AMBIENT + EXAM

- Fixtures come in pairs and requires the IES files spatially located on each side of the patient bed in AGI. 
- Use the same IES file for the Right and the Left fixture as the distribution is symmetrical. Orient each IES file with the Fixture Orientation Arrow pointed toward the patient bed.
- For Ambient only Illuminance use the AMBIENT files only. 
- For Exam Illuminance use the EXAM files only. The EXAM files represent the summation of Ambient + Exam, both of which are required to be on to reach the total Exam Function output.


AMBIENT + EXAM + READER

- Fixtures come in pairs and requires the IES files spatially located on each side of the patient bed in AGI. 
- Use the same IES file for the Right and the Left fixture as the distribution is symmetrical. Orient each IES file with the Fixture Orientation Arrow pointed toward the patient bed.
- For Exam Illuminance use the EXAM files only. The EXAM files represent the summation of Ambient + Exam, both of which are required to be on to reach the total Exam Function output.
- For Reader only Illuminance use the READER Right and Left files only.
- For Ambient + Reader Illuminance use the AMBIENT files + READER Right and Left files. First place the AMBIENT files into your layout. Then place the READER to where is overlaps the AMBIENT and top of both fixtures align. Orient each IES file with the Fixture Orientation Arrow pointed toward the patient bed.


PLEASE NOTE: 
 
- FMA8LE and FMA8LR Ambient performance is the same, therefore FMA8LE IES files can be used for both.  
- Each Right and Left file will need to be imported and placed into AGi32 separately and spaced appropriately per your room layout. 
- When locating any of the files into an AGi32 room, ensure that the fixture Orientation Arrow is pointed towards the Patient Bed. This will ensure that Photometric output is directed toward the Patient Bed.